Voltage Configuration:
120/240VAC Split ?
120/208VAC Split ?
Operating Frequency:
50/60Hz
Max. Continuous Current:
40 Amps
Under-voltage Protection Level:
104VAC (L-G)
Over-voltage Protection Level:
130VAC (L-G)
Short Cycle Delay:
3 Minutes (Default)
30 Seconds (Selectable)
Surge Current Rating:
50,000A
Connection Method:
Series-wired, ½” NPT Conduit
Hardwired lugs: 6 AWG Max
Housing:
UL Type 4X Enclosure
Dimensions:
6.29“ L x 6.29“ W x 2.36“ H
(160 mm x 160 mm x 60 mm)
Weight:
3 lb (1.36 kg)
- Protection for under-voltage & over-voltage events
- Safely disconnects power to the system allowing input voltage to return to normal range
- Diagnostic red and green LEDs indicate exactly what voltage condition is present
- Surge protection components included to divert harmful transient voltages away from the equipment